FMD-015 Small Volume Meter Prover

FMD015 SMALL VOLUME METER PROVER

SPECIFICATIONS

The FMD-015 small volume meter prover provides exceptional performance, quality, and field durability, making the FMD family of provers an exceptional choice for all your proving applications, not matter how complex.

Designed for a wide range of liquid measurement applications (see our Applications Specific Prover Page or our Frequently Asked Questions for additional application information)

  • All FMD Provers conform to API MPMS Chapter 4 Standards
  • Materials of Construction: Stainless Steel – 304 or 316, Duplex Steel
  • Standard flange size: 4″ ANSI B16.5
  • 1″ drain flanges, 2″ thermowell vents

ADDITIONAL SPECIFICATIONS

FMD-015 Displaced Volume
GallonsLiters*
PrimarySecondaryPrimarySecondary
1084030
*Please Note: Standard prover volume is in gallons, liters are optional. Prover requires non-standard switchbar for liters. Alternate displaced volumes are available for liters, please contact factory for additional information. 
FMD Prover Dimensional Drawing
FMD-015 Small Volume Prover Dimensions
Pressure RatingABCDEFGHJKLMNPQRSTU
150#52.2047.7518440.5073.7536.3110930309521325.7544.7522.75369.7582.759.00
300#52.2047.7518440.5073.7536.3110930309521325.7544.7522.75369.7582.759.38
600#52.2047.7518440.5073.7536.3110930309521325.7544.7522.75369.7582.7510.25
900#52.2047.7518440.5073.7536.3110930309422325.8844.7522.003610.0082.7511.00
Drawings Notes:
1. Dimensions “K” and “L” are for center of gravity within 6 inches. 2.Spacial dimensions have a tolerance of 1.00 inches. 3. Dimension “P” is inlet-to-outlet flange distance, drains and vents may vary. 4. All FMD-130 600# and FMD-200 models have 8 lifting lugs. Table gives dimensions to outermost lugs. 5. All dimensions are subject to change without notice. 6. For TT configurations see specific outline. 7. Dimension “H” is the distance required to remove fully assembled piston assembly from the prover. Complete seal change may be done with piston not completely removed which requires 32”(FMD-007 thru FMD-130) and 42” (FMD-200 & FMD-200 EV50).
FMD-015 WeightsANSI Pressure – 150#ANSI Pressure – 300#ANSI Pressure – 600#ANSI Pressure – 900#
Weight +/- 5%LBSKGSLBSKGSLBSKGSLBSKGS
2,8051,2752,8401,2902,8801,3103,1501,430
Weight with Crate +/- 5%3,4351,5603,4701,5803,5101,6003,7801,720
Weight filled with Water +/- 5%3,0151,3703,0551,3903,0901,4103,3601,530
FMD 015 – Motor Voltage – Phase Availability – Amperage Draw
Motor HP24 VDC120 VAC208-240 VAC380-415 VAC440-480 VAC
Single Phase1-3 Phase3 Phase3 Phase
50-60 Hz50-60 Hz50-60 Hz50-60 Hz
1.040136.521.6

FMD-015 Approvals and Certifications

ISO9001:2015, 17025:2005
ECMach Dir:2006/42/EC, EN 12100-2:2003, ATEX Dirrective 94/9/EC, EN 13463-1:2009, EN 13463-S:2003, EN 60079-0, EN60079-7, EN060079-11
CSA (US & Canada)Class 3218 06, Class 1 Div 1 Group D; Class 1 Div 2 Group D / Clutch & Brake Assembly – EX  m IIC T5
IECExUSA/ETL/QAR 15.0014/00, 101653329CRT-002
ABSACRN: OF1072.2